MIL-DTL-62422D(AT)
contrary evidence satisfactory to the contracting officer is furnished by the contractor. The
Government shall not accept products until first article inspection is completed to the satisfaction
of the Government.
TABLE II. Classification of defects.
Method of
Category
Defect
inspection
Critical:
001
Optical density not as specified (see 3.5.1).
SIE 1/
Major:
101
Materials not as specified (see 3.2).
Visual
102
Dimensions and tolerances, cleanliness, and
Visual and SIE
workmanship not as specified (see 3.3).
103
Photopic transmission not as specified (see 3.5.2).
Visual and SIE
104
Chromatically not as specified (see 3.5.3).
Visual and SIE
105
Resolution not as specified (see 3.5.4).
Visual and SIE
106
Surface quality not as specified (see 3.5.6.3).
Visual and SIE
1/ SIE = Standard Inspection Equipment
TABLE III. Classification of inspections.
Conformance
First
Title
Requirement
Inspection
article
Examinations
Tests
Optical density, first
3.5.1
4.5.3.1
X
article
Optical density
3.5.1
4.5.3.2
X
X
Optical density scan
3.5.1
4.5.3.3
X
X
Ruby coating
3.5.1.1
4.5.4
X
X
characterization
Photopic transmission
3.5.2
4.5.5
X
X
Chromaticity
3.5.3
4.5.6
X
X
Resolution
3.5.4
4.5.7
X
X
Filter coating durability
3.5.5
4.5.8
X
X
Surface quality
3.5.6
4.5.9
X
X
Laser damage resistance
3.5.7
4.5.10
X
Temperature stability
3.5.8
4.5.11
X
X
Environmental
3.4
4.5.2
X
weathering
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744